+91-1762-231491, 231334
Test |
Test Requirements |
Test Methods |
|
8N/mm2 (min.) 200% (min.) 1012 Ω-Cm (min.) 10 kV/mm (min.) -55°C to +130°C No Cracking, Dropping 50-70 No Cracking 0.5% (max.) |
ESI-09-13, ASTM D 2671 ESI-09-13, ASTM D 2671
ASTM D 257 IEC 243
ASTM D 2671 ISO 868 ASTM D 2671 |
Product Code |
As Supplied |
After Recovery |
|||
D1(max) |
D2(max) |
D1(max) |
D2(max) |
t (min.) |
|
ARSL-36/10 |
36 |
10 |
38 |
9 |
2.4 |
ARSL-55/13 |
55 |
13 |
57 |
13 |
2.5 |
ARSL-85/20 |
85 |
20 |
85 |
20 |
3.0 |
ARSL-108/27 |
108 |
27 |
110 |
27 |
3.0 |
ARSL-136/30 |
136 |
30 |
138 |
30 |
3.2 |
ARSL-180/50 |
180 |
50 |
183 |
50 |
3.2 |
* We reserve the right to make any technical changes or modify in content.